Rambler's Top100
Research-Manufacturing Enterprise METRA - World Class Weighing Equipment Single point load cells are used in floor scales provided for small loads. Load cells are used in floor scales, monorail scales, conveyor scales and Hopper scaless.
Ðóññêàÿ âåðñèÿ Ðóññêèé
Home Home Catalogue Catalogue Load cells Load cells “Single-point” load cell “Single-point” load cell
About our company
News
Industrial solutions
Catalogue
Truck scales
Car scales
Crane scales
Heavy-weight scales
Floor scales
Pallet scales
Monorail scales
Conveyor scales
Hopper scales
Flow meters
Batchers
Instruments
Load cells
“Column” load cell
“S-shaped” load cell
“Single-point” load cell
“Double shear beam” load cell
“Shear beam” load cell
Software
Accessories
Additional inquiry of the information
Search
Print page Load cell Print

Single point

Single point load cells are used in floor scales provided for small loads. The structure of the load cells allows to use one load cell for the scales. Load cells are used in floor scales, monorail scales, conveyor scales and Hopper scaless.

Load cells are made of aluminium and stainless steel. Protection degree - IP 65.


Load cell model HOC manufacturer Vishay Celtron

Load cell model  HOC manufacturer Vishay Celtron
Certificate     
Load rating (t) 750, 1000, 2000 êã
Material Aluminium alloy
Operating transmission gain 2mV/V
Accuracy rating C3
Operating temperature range Ñ -20…+60
Compensated temperature span Ñ -10…+40
Storage temperature Ñ -50...+50
Number of calibration intervals, nv 3000
Sensitivity temperature coef. % / 10oÑ <=±0,015
Zero temperature coef. % / 10oÑ <=±0,026
Hysteresis %D ** <=±0,02
Nonlinearity %D ** <=±0,03
30-minutes creep. %D <=±0,02
Input impedance 410 ± 10 Ohm
Output impedance 350±3 Ohm
Supply voltage 10 V
Ultimate load % Dmax 150
Failure load % Dmax 300
Protection degree IP 65
Cable length 3 m
Application Floor scales, Monorail scales

Load cell model LOC manufacturer Vishay Celtron

Load cell model LOC manufacturer Vishay Celtron
Certificate       
Load rating (t) 100, 150, 250, 300, 500, 635 êã
Material Aluminium (anodized)
Operating transmission gain 2mV/V
Accuracy rating C3
Operating temperature range Ñ -20…+60
Compensated temperature span Ñ -10…+40
Storage temperature Ñ -50...+50
Number of calibration intervals, nv 3000
Sensitivity temperature coef. % / 10oÑ <=±0,0110
Zero temperature coef. % / 10oÑ <=±0,0168
Hysteresis %D ** <=±0,0167
Nonlinearity %D ** <=±0,016
30-minutes creep. %D <=±0,024
Input impedance 410 ± 10 Ohm
Output impedance 350±3 Ohm
Supply voltage 1...15 V
Ultimate load % Dmax 150
Failure load % Dmax 300
Protection degree IP 65
Cable length 2,7 m
Application Floor scales, Batch bin

Load cell model LPS manufacturer Vishay Celtron

Load cell model LPS manufacturer Vishay Celtron
Certificate       
Load rating (t) 3, 6, 15, 35 êã
Material Aluminium (anodized)
Operating transmission gain 2mV/V
Accuracy rating C3
Operating temperature range Ñ -20…+60
Compensated temperature span Ñ -10…+40
Storage temperature Ñ -50...+50
Number of calibration intervals, nv 3000
Sensitivity temperature coef. % / 10oÑ <=±0,0110
Zero temperature coef. % / 10oÑ <=±0,0168
Hysteresis %D ** <=±0,0167
Nonlinearity %D ** <=±0,016
30-minutes creep. %D <=±0,024
Input impedance 410 ± 10 Ohm
Output impedance 350±3 Ohm
Supply voltage 1...15 V
Ultimate load % Dmax 150
Failure load % Dmax 300
Protection degree IP 65
Cable length 0,3 m
Application Floor scales, Batch bin

Load cell model Ì5064 manufacturer ÍÏÏ Ìåtðà

Load cell model Ì5064 manufacturer ÍÏÏ Ìåtðà
Load rating (t) 25, 50, 100, 200 êã
Material Stainless steel
Operating transmission gain 2mV/V
Accuracy rating C3
Operating temperature range Ñ -30…+40
Compensated temperature span Ñ -10…+40
Storage temperature Ñ -50...+50
Number of calibration intervals, nv 3000
Sensitivity temperature coef. % / 10oÑ <=±0,01
Zero temperature coef. % / 10oÑ <=±0,016
Hysteresis %D ** <=±0,02
Nonlinearity %D ** <=±0,02
30-minutes creep. %D <=±0,02
Input impedance 370 ± 20 Ohm
Output impedance 352±3 Ohm
Supply voltage 5...15 V
Ultimate load % Dmax 150
Failure load % Dmax 200
Protection degree IP 67
Cable length 3 m
Application Floor scales

Back to Top Single-point load cell - Back to Top