Single point
Single point load cells are used in floor scales provided for small loads. The structure of the load cells allows to use one load cell for the scales. Load cells are used in floor scales, monorail scales, conveyor scales and Hopper scaless.
Load cells are made of aluminium and stainless steel. Protection degree - IP 65.
|
Load cell model HOC manufacturer Vishay Celtron |
|
|
|
Certificate
 |
| Load rating (t) |
750, 1000, 2000 êã |
| Material |
Aluminium alloy |
| Operating transmission gain |
2mV/V |
| Accuracy rating |
C3 |
| Operating temperature range Ñ |
-20…+60 |
| Compensated temperature span Ñ |
-10…+40 |
| Storage temperature Ñ |
-50...+50 |
| Number of calibration intervals, nv |
3000 |
| Sensitivity temperature coef. % / 10oÑ |
<=±0,015 |
| Zero temperature coef. % / 10oÑ |
<=±0,026 |
| Hysteresis %D ** |
<=±0,02 |
| Nonlinearity %D ** |
<=±0,03 |
| 30-minutes creep. %D |
<=±0,02 |
| Input impedance |
410 ± 10 Ohm |
| Output impedance |
350±3 Ohm |
| Supply voltage |
10 V |
| Ultimate load % Dmax |
150 |
| Failure load % Dmax |
300 |
| Protection degree |
IP 65 |
| Cable length |
3 m |
| Application |
Floor scales, Monorail scales |
|
 |
Load cell model LOC manufacturer Vishay Celtron |
|
|
Certificate
 |
| Load rating (t) |
100, 150, 250, 300, 500, 635 êã |
| Material |
Aluminium (anodized) |
| Operating transmission gain |
2mV/V |
| Accuracy rating |
C3 |
| Operating temperature range Ñ |
-20…+60 |
| Compensated temperature span Ñ |
-10…+40 |
| Storage temperature Ñ |
-50...+50 |
| Number of calibration intervals, nv |
3000 |
| Sensitivity temperature coef. % / 10oÑ |
<=±0,0110 |
| Zero temperature coef. % / 10oÑ |
<=±0,0168 |
| Hysteresis %D ** |
<=±0,0167 |
| Nonlinearity %D ** |
<=±0,016 |
| 30-minutes creep. %D |
<=±0,024 |
| Input impedance |
410 ± 10 Ohm |
| Output impedance |
350±3 Ohm |
| Supply voltage |
1...15 V |
| Ultimate load % Dmax |
150 |
| Failure load % Dmax |
300 |
| Protection degree |
IP 65 |
| Cable length |
2,7 m |
| Application |
Floor scales, Batch bin |
|
 |
Load cell model LPS manufacturer Vishay Celtron |
|
|
Certificate
 |
| Load rating (t) |
3, 6, 15, 35 êã |
| Material |
Aluminium (anodized) |
| Operating transmission gain |
2mV/V |
| Accuracy rating |
C3 |
| Operating temperature range Ñ |
-20…+60 |
| Compensated temperature span Ñ |
-10…+40 |
| Storage temperature Ñ |
-50...+50 |
| Number of calibration intervals, nv |
3000 |
| Sensitivity temperature coef. % / 10oÑ |
<=±0,0110 |
| Zero temperature coef. % / 10oÑ |
<=±0,0168 |
| Hysteresis %D ** |
<=±0,0167 |
| Nonlinearity %D ** |
<=±0,016 |
| 30-minutes creep. %D |
<=±0,024 |
| Input impedance |
410 ± 10 Ohm |
| Output impedance |
350±3 Ohm |
| Supply voltage |
1...15 V |
| Ultimate load % Dmax |
150 |
| Failure load % Dmax |
300 |
| Protection degree |
IP 65 |
| Cable length |
0,3 m |
| Application |
Floor scales, Batch bin |
|
 |
Load cell model Ì5064 manufacturer ÍÏÏ Ìåtðà |
|
|
| Load rating (t) |
25, 50, 100, 200 êã |
| Material |
Stainless steel |
| Operating transmission gain |
2mV/V |
| Accuracy rating |
C3 |
| Operating temperature range Ñ |
-30…+40 |
| Compensated temperature span Ñ |
-10…+40 |
| Storage temperature Ñ |
-50...+50 |
| Number of calibration intervals, nv |
3000 |
| Sensitivity temperature coef. % / 10oÑ |
<=±0,01 |
| Zero temperature coef. % / 10oÑ |
<=±0,016 |
| Hysteresis %D ** |
<=±0,02 |
| Nonlinearity %D ** |
<=±0,02 |
| 30-minutes creep. %D |
<=±0,02 |
| Input impedance |
370 ± 20 Ohm |
| Output impedance |
352±3 Ohm |
| Supply voltage |
5...15 V |
| Ultimate load % Dmax |
150 |
| Failure load % Dmax |
200 |
| Protection degree |
IP 67 |
| Cable length |
3 m |
| Application |
Floor scales |
|
 |
|
|