Rambler's Top100
Research-Manufacturing Enterprise METRA - World Class Weighing Equipment S-beam load cells are used for reservoirs or other suspended structures weighing, and also for tensile or pressing load measuring. Load cells are used in hopper scales and Hopper scaless.
Ðóññêàÿ âåðñèÿ Ðóññêèé
Home Home Catalogue Catalogue Load cells Load cells “S-shaped” load cell “S-shaped” load cell
About our company
News
Industrial solutions
Catalogue
Truck scales
Car scales
Heavy-weight scales
Crane scales
Floor scales
Pallet scales
Monorail scales
Conveyor scales
Hopper scales
Flow meters
Batchers
Instruments
Load cells
“Column” load cell
“S-shaped” load cell
“Single-point” load cell
“Double shear beam” load cell
“Shear beam” load cell
Software
Accessories
Additional inquiry of the information
Search
Print page S-beam load cell Print

S-beam load cell

S-beam load cells are used for reservoirs or other suspended structures weighing, and also for tensile or pressing load measuring. Load cells are used in hopper scales and Hopper scaless.

Load cells are made of steel, they are absolutely waterproof, protection degree - IP 67.


Load cell model 60001 manufacturer Vishay Sensortronics

Load cell model 60001 manufacturer Vishay Sensortronics
Certificate         
Load rating (t) 50, 100, 250, 500, 1000, 2500, 5000, 10000 êã
Material Tool steel; electrolytic nickel coating
Operating transmission gain 3mV/V
Accuracy rating C3
Operating temperature range Ñ -30…+40
Compensated temperature span Ñ -10…+40
Storage temperature Ñ -50...+85
Number of calibration intervals, nv 3000
Sensitivity temperature coef. % / 10oÑ <=±0,0110
Zero temperature coef. % / 10oÑ <=±0,0168
Hysteresis %D ** <=±0,0167
Nonlinearity %D ** <=±0,016
30-minutes creep. %D <=±0,024
Input impedance 343 - 450 Ohm
Output impedance 349 - 355 Ohm
Supply voltage 2…10 V
Ultimate load % Dmax 150
Failure load % Dmax 300
Protection degree IP 67
Cable length 6 m
Application Hopper scales, Batch bin

Load cell model STC manufacturer Vishay Celtron

Load cell model STC manufacturer Vishay Celtron
Certificate     
Load rating (t) 25, 50, 75, 100, 150, 200, 250, 300, 500, 750, 1000, 1500, 2000 êã
Material Tool steel; electrolytic nickel coating
Operating transmission gain 3mV/V
Accuracy rating 0,02%
Operating temperature range Ñ -20…+60
Compensated temperature span Ñ -10…+40
Storage temperature Ñ -50...+50
Number of calibration intervals, nv 3000
Sensitivity temperature coef. % / 10oÑ <=±0,0110
Zero temperature coef. % / 10oÑ <=±0,0168
Hysteresis %D ** <=±0,0167
Nonlinearity %D ** <=±0,016
30-minutes creep. %D <=±0,024
Input impedance 385 ± 5 Ohm
Output impedance 350 ± 3 Ohm
Supply voltage 2…15 V
Ultimate load % Dmax 150
Failure load % Dmax 300
Protection degree IP 67
Cable length 6 m
Application Hopper scales, Batch bin
Back to Top S-beam load cell - Back to Top
© 2010 Metra Ltd » Site Map