Shear beam
Shear beam load cells are used for reservoir and hopper weighing in floor scales range 300 kg – 10 tons. They are used in floor scales, monorail scales, conveyor scales, hopper scales and Hopper scaless.
Load cells are made of steel and stainless steel, protection degree IP 65 and IP 67.
|
 |
Load cell model 65023Ñ manufacturer Vishay Sensortronics |
|
|
Certificate
 |
| Load rating (t) |
250, 500, 750, 1000, 2000, 5000, 10000 êã |
| Material |
Tool steel; electrolytic nickel coating |
| Operating transmission gain |
3mV/V |
| Accuracy rating |
C3 |
| Operating temperature range Ñ |
-18…+65 |
| Compensated temperature span Ñ |
-10…+40 |
| Storage temperature Ñ |
-50...+85 |
| Number of calibration intervals, nv |
3000 |
| Sensitivity temperature coef. % / 10oÑ |
<=±0,0110 |
| Zero temperature coef. % / 10oÑ |
<=±0,0168 |
| Hysteresis %D ** |
<=±0,0167 |
| Nonlinearity %D ** |
<=±0,016 |
| 30-minutes creep. %D |
<=±0,024 |
| Input impedance |
343 - 357 Ohm |
| Output impedance |
349 - 355 Ohm |
| Supply voltage |
2...10 V |
| Ultimate load % Dmax |
150 |
| Failure load % Dmax |
300 |
| Protection degree |
IP 67 |
| Cable length |
6 m |
| Application |
Floor scales,hopper scales, hopper, reservoir plant |
|
 |
Load cell model HLCBC3 manufacturer HBM |
|
|
Certificate
 |
| Load rating (t) |
200, 550, 1100, 1760, 2200, 4400 êã |
| Material |
Stainless steel |
| Operating transmission gain |
2mV/V |
| Accuracy rating |
C3 |
| Operating temperature range Ñ |
-15…+70 |
| Compensated temperature span Ñ |
-10…+40 |
| Storage temperature Ñ |
-50...+85 |
| Number of calibration intervals, nv |
3000 |
| Sensitivity temperature coef. % / 10oÑ |
<=±0,0140 |
| Zero temperature coef. % / 10oÑ |
|
| Hysteresis %D ** |
<=±0,0170 |
| Nonlinearity %D ** |
<=±0,0170 |
| 30-minutes creep. %D |
<=±0,0250 |
| Input impedance |
400 ± 50 Ohm |
| Output impedance |
350±2 Ohm |
| Supply voltage |
10 V |
| Ultimate load % Dmax |
150 |
| Failure load % Dmax |
300 |
| Protection degree |
IP 68 |
| Cable length |
3 m, 6 m |
| Application |
Floor scales,hopper scales, hopper, reservoir plant |
|
 |
Load cell model Z6FC3 manufacturer HBM |
|
|
Certificate
 |
| Load rating (t) |
50, 100, 200, 500, 1000 êã |
| Material |
Stainless steel |
| Operating transmission gain |
2mV/V |
| Accuracy rating |
C3 |
| Operating temperature range Ñ |
-30…+70 |
| Compensated temperature span Ñ |
-10…+40 |
| Storage temperature Ñ |
-50...+85 |
| Number of calibration intervals, nv |
3000 |
| Sensitivity temperature coef. % / 10oÑ |
<=±0,0080 |
| Zero temperature coef. % / 10oÑ |
<=±0,0125 |
| Hysteresis %D ** |
<=±0,0170 |
| Nonlinearity %D ** |
<=±0,0180 |
| 30-minutes creep. %D |
<=±0,0166 |
| Input impedance |
430 ± 50 Ohm |
| Output impedance |
356±0.12 Ohm |
| Supply voltage |
0.5...12 V |
| Ultimate load % Dmax |
150 |
| Failure load % Dmax |
300 |
| Protection degree |
IP 67 |
| Cable length |
3 m |
| Application |
Floor scales,hopper scales,batch bins, hopper, reservoir plant |
|
 |
Load cell model Ì5023 manufacturer ÍÏÏ Ìåtðà |
|
|
| Load rating (t) |
375, 550, 750, 1100, 1500 êã |
| Material |
Stainless steel |
| Operating transmission gain |
3mV/V |
| Accuracy rating |
C3 |
| Operating temperature range Ñ |
-30…+40 |
| Compensated temperature span Ñ |
-10…+40 |
| Storage temperature Ñ |
-50...+50 |
| Number of calibration intervals, nv |
3000 |
| Sensitivity temperature coef. % / 10oÑ |
<=±0,01 |
| Zero temperature coef. % / 10oÑ |
<=±0,0168 |
| Hysteresis %D ** |
<=±0,0167 |
| Nonlinearity %D ** |
<=±0,016 |
| 30-minutes creep. %D |
<=±0,024 |
| Input impedance |
370 ± 20 Ohm |
| Output impedance |
352±3 Ohm |
| Supply voltage |
2...10 V |
| Ultimate load % Dmax |
150 |
| Failure load % Dmax |
300 |
| Protection degree |
IP 67 |
| Cable length |
3 m |
| Application |
Floor scales, Monorail scales, Batch bin, hopper, reservoir plant |
|
 |
|
|