Home Home Catalogue Catalogue Instruments Instruments Batching weight-measuring instrument Batching weight-measuring instrument
About our company
News
Industrial solutions
Catalogue
Truck scales
Car scales
Crane scales
Heavy-weight scales
Floor scales
Pallet scales
Monorail scales
Conveyor scales
Hopper scales
Flow meters
Batchers
Instruments
Weight-measuring instrument for static scales
Batching weight-measuring instrument
Conveyor weight-measuring instrument
Ì0801 Digital load cell signal converter
Load cell signal simulator
Backup panel
Interface connector
Remote control unit
Control cabinet for discrete batcher
Control cabinet for continuous batcher
Microsim 0601-BM Weight-measuring instrument
Ì0803
Load cells
Software
Accessories
Additional inquiry of the information
Search
Print page Microsim – 06D Print
Ìèêðîñèì - 06Ä Ïðèáîð âåñîèçìåðèòåëüíûé äîçèðóþùèé

Ìèêðîñèì - 06Ä Ïðèáîð âåñîèçìåðèòåëüíûé äîçèðóþùèé

Ìèêðîñèì - 06Ä Ïðèáîð âåñîèçìåðèòåëüíûé äîçèðóþùèé

Microsim – 06D
Weight-measuring batching instrument

Designation: It is used as a part of discrete batcher or technological equipment with various load cells.

Benefits:

  • Wide scope of automation, stock-taking, weighing results registration;
  • Calibration values of “Microsim-06D”-based weighing system are protected with password and “electronic seal”. They are saved in volatile storage, number of rewriting cycles is not less than 100000;
  • Reliable dust- and drip-proof aluminum case with membranous front panel;
  • U-shaped support allows to regulate instrument body slope;
  • Harnesses allow to mount the instrument in a cabinet;
  • Galvanic isolated discrete inputs/outputs.

Standard functions:

  • Output of “gross”, “net”, “tare” values for indication;
  • automatic and manual indication zeroing;
  • zero self-tuning;
  • accumulation and indication of resulting amount of several weighing processes, total value display;
  • Rate of exchange up to 9600 baud;
  • Parallel connection of several load cells (from 1 to 8) with total resistance not less than 80 Ohm;
  • The device is equipped with galvanic isolated COM-port for operation via RS485 interface;
  • The device is equipped with input-output module "Ì2604" with galvanic isolated inputs/outputs.

Extended functions:

  • A programmable input/output module “Ì2606” with programmed batching algorithm can be setup.

A floppy disc with driver DevCom and examples of its call from 1C, Access and other programs is included in the delivery set.

Modifications and their basic specifications
Characteristics Ì0600-D4-02 Ì0600-D4-04
Galvanic isolated COM-port RS485 + +
Driver DevCom + +
Programmable input/output module Ì2606   +
Galvanic isolated discrete inputs/outputs + +

External batcher inputs:
ON Switch from “scales” mode to “batcher” mode
TARE Current weight should be taken as “tare”
START Save current “gross” weight as a “base” for stock-taking, start the batching process
STOP Calculate “actual doze”, finish the batching process
OFF Switch from “batcher” mode to “scales” mode

External batcher outputs
MEANDER The batcher is able to work and is in “batcher” mode
EXIT-0 Set value-0 is exceededà
EXIT-1 Set value-1 is exceeded
EXIT-2 Set value-2 is exceeded
RESPONSE A signal is received and is being processes
ERROR If there is a logical inconsistency between the set values
CYCLE The device is in batching process

"Microsim-0600-D6-04" has 8õ8 DIO (programmable inputs and outputs). Inputs/outputs designation depends on the batching algorithm.

Standard algorithms:

  • “rough”, “accurate” batching;
  • Dose collection with the following packing;
  • Unit dosing and other.
A program based on the customer’s algorithm can be developed on request.

If you need to connect several scales to one PC using network bus RS485, you should use interface connector “INCON-MT” and the driver "DEVNet", supplied on request.

Driver DevCom provides basic set of communication functions. It allows to setup connection, to transfer operator’s commands to the scale terminal, to take weighing results, display them and also transfer them to the backup indicator panel (if any). It also has the same functions if DevCom is started from the user application (examples for 1C, Access, Delphi are enclosed).
Technical specification
Characteristic Unit Value
Load cell supply voltage (DC or AC of Meander type) V 5±0,5
Minimum load cell(s) resistance Ohm 80
Working range of load cell signal mV/V -0,05…2,55
Number of inputs for load cell connection pcs 6
Length of load cell connection line, not more m 100
Main reduced error of load cell signal conversion to a code, not more % 0,01
Height of indication symbolsè mm 14
Weight with external power supply and a pedestal, not more kg 1,5
Power consumption, not more VA 15
Supply voltage V 220+22-33

Additional equipment
Ìàðêà, îáîçíà÷åíèå Õàðàêòåðèñòèêà
INCON-MT Interface connector for RS232-C to RS-485 conversion at the computer side
M1900 Backup indicator panel, small(height of indication symbols = 14mm)
Ì1901 Backup indicator panel, large (height of indication symbols = 100mm)
DevNet Driver for network connection through RS485
RS485 Cable for connection via RS485 (2 or 10m long)